GE Dash 4000 Vital Signs Monitor – Recertified

SKU: GEDASH4-AEAG-AAXX-XXXX-R

Ge-healthcare-logo

LEGACY UNIT: This product has been discontinued and is no longer available to purchase new. There is a replacement model, the GE Procare B40 Vitals Monitor, that is available here on our site if you need a new unit.

MME no longer carries Dash 4000 units. We recommend the B40, Mindray products, or Edan products.

 

The GE Dash 4000 Monitor features:

  • Color Display 3-Lead ECG
  • Sp02
  • Dinamap NIBP Temperature
  • Printer
  • Battery
  • 1-Year MME Warranty

Smart Anesthesia Multi-Gas (SAM®) module provides breath-by-breath analysis of respiratory and anesthetic gases. SAM also instantaneously identifies and quantifies agents, alone or in a mixture.

The DASH 4000 provides revolutionary chest pain care as it was the first monitor to incorporate ACI-TIPI (Acute Cardiac Ischemia Time-Insensitive Predictive Instrument). The DASH 4000 automatically calculates a patient’s probability of Acute Coronary Ischemia from 0 to 100% which is shown to reduce the number of unnecessary admits to the CCU while helping to confirm appropriate admissions.

The GE Dash 4000 patient data can be used retrospectively or in real-time clinical decisions. GE’s 12SL® remains the industry’s most thorough 12-lead analysis for sensitivity and specificity while Dinamap NiBP sets the Gold Standard for accuracy in every Dash 4000. The Dinamap technology built-in to this unit consistently produces the most accurate and reliable NiBP measurements.

If you are eligible for exemption from sales tax, please call or email us to place your order. All orders completed online will have applicable sales tax added.

 

GE Dash 4000 Technical Specifications

Dimensions

  • Height: 27.4 cm. Depth: 24.3 cm. Width: 29.3 cm.
  • Weight: 5.7 kg

Display

  • Size: 26 cm (diagonal).
  • Type: active-matrix color TFT.
  • Resolution: 640 by 480 pixels.
  • Number of traces: 6 maximum.
  • Number of seconds/trace: 4.9 at 25 mm/sec.
  • Sweep speed: 6.25, 12.5, 25 mm/sec (with erase bar).
  • Information window: displays non-real-time information without obstructing the display of real-time information.
  • Display organization: prioritized by parameter.

Controls

  • Trim Knob® control.
  • Five hard keys: silence alarm, graph go/stop, function (zero all) and power on/off.

Alarms

  • Categories: patient status and system status.
  • Priority: 4 levels – crisis, warning, advisory, and message.
  • Notification: audible and visual.
  • Setting: default and individual.
  • Silencing: 1 minute, current alarm only.
  • Pause: 5 minutes in adult ICU mode, 3 minutes in neonatal ICU mode, and 5,15, or permanent pause in OR mode.
  • Volume: default 70%, 70 dB measured at 1 meter.

ECG

  • Standard leads available: I, II, III, V, aVR, aVL, and aVF. 10
  • lead wire cable: I, II, III, V, aVR, aVF, V2, V3, V4, V5, V6.
  • Leads analyzed simultaneously: I, II, III, and V (multi-lead mode).
  • Lead fail: identifies failed lead.
  • Alarms: user-selectable upper and lower heart rate limits.

Input Specifications

  • Voltage range: ±0.5 mV to ±5 mV.
  • Signal width: 40 ms to 120 ms (Q to S).
  • Heart rate range: 30 to 300 bpm.
  • Input impedance: common mode > 10 Mat 50/60 Hz, differential > 2.5 Mfrom dc to 60 Hz.
  • Common mode rejection: 90 dB minimum at 50 or 60 Hz

Respiration

  • Measurement technique: impedance variation detection.
  • Range respiration rate: 0 – 200 breaths per minute.
  • Base impedance: 100 – 1000 Ωat 52.6 kHz.
  • Detection sensitivity: 0.4 to 10 Ωvariation.
  • Waveform display bandwidth: 0.1 to 1.8 Hz (-3 dB).
  • Alarms: user-selectable upper and lower respiration limits, and user-selectable apnea limit.

Temperature

  • Number of channels: 2.
  • Input specifications – probe type: YSI series 400 or 700,
  • temperature range: 0°C to 45°C (32°F to 113°F),
  • resolution: ±0.1°C.
  • Output specifications – parameters displayed: T1, T2,
  • accuracy: ±0.1°C for YSI series 4000 probes, ±0.3°C for YSI series 7000 probes, independent of source.
  • Alarms: user-selectable upper and lower limits for T1 and T2.

Invasive Blood Pressure

  • Number of channels: 2 (optional).
  • Transducer sites: arterial, femoral artery, pulmonary arterial, central venous, right atrial, left atrial, intracranial, and special.
  • Transducer requirements: 5 Vdc±0.1% excitation voltage.
  • Transducer output: 5 μV/V/mmHg. Input specifications – range: -25 mmHg to 300 mmHg, offset: ±150 mmHg.
  • Output specifications – frequency response: dc to 50 Hz (-0/+2 Hz).
  • Zero balance range: ±150mmHg.
  • Zero balance accuracy: ±1mmHg.
  • Zero balance drift: ±1mmHg over 24 hours.
  • Accuracy: ±2% or ±1mmHg, whichever is greater.
  • Alarms: user- selectable upper and lower limits for systolic, diastolic, and mean pressures.

NIBP

  • Measurement technique: oscillometric.
  • Displayed parameters; systolic, diastolic, and mean pressures.
  • Systolic: 30-275 mmHg adult, 30-235 mmHg pediatric, and 30-135 mmHg neonate.
  • Diastolic: 10-220 mmHg adult, 10-220 mmHg pediatric, and 10-110 mmHg neonate.
  • MAP: 20-260 mmHg adult, 20-260 mmHg pediatric, and 20-125 mmHg neonate.
  • Pulse rate, as displayed in tabular trends: 30-200 bpm adult, 30-200 bpm pediatric, and 30-200 bpm neonate

Pulse Oximetry

  • Parameters monitored: arterial oxygen saturation (SpO2) and peripheral pulse rate (PPR).
  • SpO2range: 50 –100%. PPR range: 30-300 beats per minute.
  • SpO2 accuracy: ±2% (70-100%) and ±3% (50- 69%).
  • PPR accuracy: ±3 beats per minute.
  • Alarms: user-selectable upper and lower limits for SpO2 and PPR.

C02

  • Information displayed: inspired and expired CO2 concentrations in %, mmHg, or kPa, respiratory rate, and continuous CO2 waveform.
  • Measurement ranges: PiCO2/FiCO2: 0 to 100 mmHg/0to13%. Pe CO2/ Fe CO2: 0 to 100 mmHg/0 to 13%;
  • RR: 0 to 120 breaths/min.
  • Accuracy: CO2: 5% of reading or ±2 mmHg, whichever is greater.
  • Display resolution: 1 mmHg. Rise time: less than 60 msec.
  • Respiration rate accuracy: ± breath/min
Weight 15 lbs
Dimensions 15 × 15 × 15 in