SSCOR – Battery-Powered Portable Suction Unit – DM10-001

$1,250.00

Hours of Medical Vacuum Using DCell Alkaline Batteries
Designed for disaster preparedness, the DCell runs for six to nine hours on a set of off the shelf alkaline D-Cell batteries. A 60 second battery change gives you another six to nine hours of quality medical vacuum.

FEATURES:

  • Variable regulator and gauge
  • Battery condition indicator
  • Does not need to be kept on charge
  • Power options include: 12V DC power using the SSCOR #80665 DC power cord or AC power using the SSCOR #200-00001 AC power converter.
  • Accommodates most standard hospital suction canisters
  • Canister can be oriented in one of three positions
  Total: 

Hours of Medical Vacuum Using DCell Alkaline Batteries
Designed for disaster preparedness, the DCell runs for six to nine hours on a set of off the shelf alkaline D-Cell batteries. A 60 second battery change gives you another six to nine hours of quality medical vacuum.

FEATURES:

  • Variable regulator and gauge
  • Battery condition indicator
  • Does not need to be kept on charge
  • Power options include: 12V DC power using the SSCOR #80665 DC power cord or AC power using the SSCOR #200-00001 AC power converter.
  • Accommodates most standard hospital suction canisters
  • Canister can be oriented in one of three positions

SPECIFICATIONS:

  • Performance: Clinical airflow >=30 lpm, <50 mmHg to >525 mmHg vacuum (specifications based on tests performed with fresh Duracell alkaline batteries)
  • Vacuum Pump: 12V DC; Exceeds -525mmHg for the first few hours and exceeds 300mmHg for the stated run time*
  • External Power Source Adapters: Power options include: 12V DC power using the SSCOR #80665 DC power cord or AC power using the SSCOR #200-00001 AC power converter.
  • Power: 12V DC 1A
  • Battery: Off- the-shelf 12xD Cell Alkaline Batteries (not included)
  • Run Time: 6-9 Hours*
  • Standard Items Included With Product: 1200cc Canister, 2m patient tube, HI-D® Suction Tip and Quickstart Guide
  • Conforms To: EC 60601-1, IEC 60601-1-2, IPX4, ETL Listed
  • Reference / Model Number: DM10-001

Batteries not included.

*Run time is defined as the period of time that the device generates more than 300 mmHg negative pressure. Total run time typically varies between 6-9 hours. These run time specifications are based upon tests using new Duracell® CopperTop batteries. Run time will vary depending on battery manufacturer, state of the charge, ambient temperature, and age of the batteries.

Accessories and Components

  • SSCOR – Ducanto Catheter (Case of 50) – 200-00002C

    $111.50
    Add to cart
  • SSCOR – Patient Connecting Tubing 9/32″ x 6′ – 43200C

    $94.00
    Add to cart

Weight 9.5 lbs
Dimensions 12 × 10 × 13 in
Condition