Hamilton T1 Highlight

Hamilton T1 Ventilator

The Industry-leading transport ventilator

The Hamilton T1 Offers:

  • Approvals and certificates for use in ambulances, helicopters and airplanes
  • Adult, pediatric, and optional neonatal ventilation
  • Independence from gas cylinders or compressors
  • More than 9 hours of battery operating time
  • Noninvasive ventilation and optional integrated high flow oxygen therapy
  • Advanced ventilation modes, including ASV® – Adaptive Support Ventilation

The Hamilton T1 Features:

  • Adult, pediatric, and optional neonatal ventilation
  • High-performance turbine
  • Hot-swappable battery backup
  • IntelliTrig leak compensation for NIV and invasive ventilation
  • Serial interface for connection to electronic patient data records and patient monitors
  • Mainstream (volumetric) and sidestream capnography
  • Pulse oximetry (SpO2 and pulse measurement)
  • nCPAP modes
  • Configurable loops and trends
  • Optimal alarm detection
  • Dynamic Lung
  • Fully synchronized integrated pneumatic nebulizer
  • Compatible with conventional speaking valves
Lung Protective Ventilation
The HAMILTON-T1 features Intelligent Ventilation mode Adaptive Support Ventilation (ASV). In ASV mode, the ventilator continuously adjusts the respiratory rate, tidal volume, and inspiratory time depending on the patient’s lung mechanics and effort. This means fewer user interactions are required and fewer alarms are generated, giving you more time for your patients. ASV automatically employs lung-protective strategies to minimize complications from AutoPEEP and volutrauma/barotrauma. It also prevents apnea, tachypnea, dead space ventilation, and excessively large breaths, as well as encouraging the patient to breathe spontaneously.

Approved for all types of transport
The Hamilton T1 Transport Ventilator meets the transport standards EN 794-3 and ISO 10651-3 for emergency and transport ventilators, EN 1789 for ambulances, and both EN 13718-1 and RTCA/DO-160G for aircrafts. It reliably accompanies your patients in or outside the hospital, on the ground, at sea, or in the air.
Independent from compressed air
The integrated high-performance turbine enables the HAMILTON-T1 to be completely independent from compressed air. This reduces weight and saves space, since you need neither gas cylinders nor a compressor. This allows even patients ventilated noninvasively to be transported successfully across greater distances.
9+ hours of battery operation
A battery operating time of more than 9 hours is provided by one integrated and one hot-swappable battery. The battery operating time can be extended as required with additional hot-swappable batteries.
State-of-the-art ventilation modes
Include conventional volume and pressure-controlled modes, modes for noninvasive ventilation, and the Intelligent Ventilation mode Adaptive Support Ventilation (ASV).
Quick startup
Settings allow you to define and store specific mode and control settings for up to three selected patient types. This may help you save valuable time in emergencies.
Oxygen adjustable from 21% to 100%
Allows you to replicate the bedside settings one-to-one during transport. The adjustment to 21% even makes it possible to ventilate your patient with ambient air only.
High-performance noninvasive ventilation
Is enabled by the ventilator’s integrated high-performance turbine and peak flow rate of up to 260 l/min. Optimal flow delivery is ensured even in the event of large leaks.
Integrated high flow oxygen therapy
can be applied using the same device and breathing circuit, simply by changing the patient interface. Active humidification is recommended for greater patient comfort. With the optional integrated high flow oxygen therapy, the ventilator offers you a range of ventilation and therapy options in one device.
A Recertified Hamilton T1 Purchase Includes:
  • A Recertified Hamilton T1 Transport Ventilator
  • An Adult Coaxial Circuit
  • An Adult HME Filter
  • An Expiratory Valve Set
  • An NBC Filter Set
  • A Flow Sensor
  • A 10 Ft. Oxygen Hose Assembly
  • A 1-Year Warranty, with options for extended warranties available

The HAMILTON-T1 combines the functionality of a fully featured intensive care unit ventilator with the compactness and ruggedness required for transport. This combination enables you to provide optimal ventilation therapy to all patient groups during transport. To learn more about specific configurations available and optional parameters, please fill out the “Request for Quote” form below or call 866-530-9032 to talk to a friendly and knowledgeable sales representative.