Riester RVS-100 Vital Signs Monitor with NiBP and Heart Rate Monitor

Call For Quote

Engineered for the mobile and fast recording of vital signs. Clinically validated for adults as well as newborns weighing as little as 1kg (2.2 lb). Simultaneous measurement of different vital signs within seconds.

Features:

  • Coloured 4.3“ TFT display (SYS, DIA, MAP, pulse, SpO2, Temp)
  • External wireless printer
  • Filac™ 3000 predictive oral/rectal thermometer
  • Ear thermometer
  • New mobile stand, brand-new Riester design
  • SpO2 sensors with a cable length of 1.2 m (47.24 in).
  • Efficient and lightweight rechargeable Li-ion battery pack

 

 

Description

Technical Data

Power Supply: 100 – 240 V AC, 50/60 Hz

Battery: Lithium-Ion battery, rechargeable, 10.8 V DC, 6,600 mAh, Charging time to a

100%: 6 hours, Operating time approx. 11 hours (new and fully charged battery)

Monitor Dimensions: L x H x W: 303 x 230 x 110 mm (11.93 x 9.05 x 4.33 in)

Weight: 3600 g, (7.94 lb)

Basket Dimensions: L x H x W: 270 x 225 x 200 mm (10.63 x 8.86 x 7.87 in)

Alarm: Visible LEDs (Yellow, Red, Blue, Green, Orange)

Audible Speaker

Gives audible alarm, QRS tone

Ports: 1 x AC power inlet

1 x standard RJ45 interfaces.100 BASE-TX, IEEE 802.3

4 x USB ports

1 x Equipotential grounding point

1 x RJ11 connector for nurse call

DC out port 15V/1.2 A

 

Clinical-grade NIBP (non-invasive blood pressure)

Measuring method: automatic oscillometric

Measurement range: Adult

SYS 30 – 270 mmHg, DIA 10 – 220 mmHg, MAP 20 – 235 mmHg

Pediatric

SYS 30 – 235 mmHg, DIA 10 – 220 mmHg, MAP 20 – 225 mmHg

Neonate

SYS 30-135 mmHg, DIA 10-110 mmHg, MAP 20-125 mmHg

Cuff pressure range: 0 – 280 mmHg

Resolution: 1 mmHg

Pressure accuracy: Static ±3 mmHg

Clinic ±5 mmHg, standard deviation _ 8 mmHg

Pulse rate range: 40 – 240 bpm

Pulse rate accuracy: 1 bpm

Initial inflation pressure: Adult 160 mmHg, Pediatric 130 mmHg, Neonate 75 mmHg

Double overpressure protection (hardware and software)

Adult 297 ± 3 mmHg, Pediatric 252 ± 3 mmHg , Neonate 147 ± 3 mmHg

Alarm range:

SYS 0 – 300 mmHg

DIA 0 – 300 mmHg

MAP 0 – 300 mmHg

Riester SpO2 Measurement range: 0 – 100%

Resolution: 1%

Accuracy: ±2%(70 to 100%)

±3% (40% to 69%)

Unspecified (0% to 39%)

Alarm range: 0 – 100%

Average time: 4 sec, 8 sec, 16 sec

Pulse rate

Measurement range: 20 – 250 bpm

Resolution: 1 bpm

Accuracy: ±1% or ±1 bpm whichever is greater

Nellcor SpO2 Measurement range: 0-100%

Resolution: 1%

Accuracy: 70 – 100%: ±2% (adult, pediatric)

70 – 100%: ±3% (neonate)

0 – 69%: unspecified

Alarm range: 0 – 100%

Average time: 8 sec, 16 sec

Pulse rate

Measurement range: 20 – 300 bpm

Resolution: 1 bpm

Accuracy: 20 – 250 bpm: ±3 bpm

251 – 300 bpm: unspecified

Masimo SpO2 Measurement range: 0 – 100%

Resolution: 1%

Accuracy: 70 – 100%: ±2% (adult, pediatric, non-motion conditions)

70 – 100%: ±3% (neonate, non-motion conditions)

70 – 100%: ±3% (motion conditions)

0 – 69%: unspecified

Average time: 2 – 4 sec, 4 – 6 sec, 8 sec, 10 sec, 12 sec, 14 sec, 16 sec

Pulse rate

Measurement range: 25 – 240 bpm

Resolution: 1 bpm

Accuracy: ±3 bpm (non-motion conditions)

±5 bpm (motion conditions)

Predictive thermometer

  • Oral ( Quick Mode ) non-fever temps: 3-5 seconds

fever temps: 8-10 seconds

  • Oral ( Standard Mode ): 6-10 seconds
  • Axillary Mode: 8-12 seconds
  • Rectal Mode: 10-14 seconds
  • Direct Mode (all sites): 60-120 seconds

Additional information

Weight 25 lbs
Dimensions 18 × 18 × 18 in
Condition